Halloween Special - Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: sntaclus

A building manager changes the sequence of operation for boilers to better match heating demand as a result of an ASHRAE Level 2 analysis. Which of the following is an example of an appropriate topic for training of building operations staff to continue implementation of this change and meet the requirements of Energy and Atmosphere Credit, Existing Building Commissioning - Implementation?

A.

Sensor calibration

B.

Test and balance procedures

C.

Cooling tower water management

D.

Operating schedules and requirements

What is the minimum percentage reduction from the baseline required to earn the exemplary performance point for the Indoor Water Use Reduction Credit, Option 2?

A.

20%

B.

25%

C.

30%

D.

35%

The development of a five-year plan under Sustainable Sites Credit, Site Improvement Plan contributes to the achievement of

A.

the required 100% impervious surfaces

B.

the required 3% vegetated site area

C.

Water Efficiency Credit, Cooling Tower; Sustainable Sites Credit, Joint Use of Facilities

D.

Sustainable Sites Credit, Site Management; Water Efficiency Credit, Outdoor Water Use Reduction

A project is ineligible for an ENERGY STAR® Rating and will document Energy and Atmosphere Prerequisite,

Minimum Energy Performance by benchmarking against historical data. If the performance period calendar year is

2022, which of the following is an acceptable historical baseline?

A.

Average of calendar years 2020 and 2021

B.

Average of calendar years 2015, 2016 and 2017

C.

Average of calendar years 2017, 2019 and 2021

D.

Average of calendar years 2017, 2018 and 2019

For an office building with few visitors, which of the following actions must the project team do in order to comply with Location and Transportation Credit, Alternative Transportation?

A.

Encourage telecommuting and the use of mass transit

B.

Survey visitors to determine their transportation modes

C.

Survey the occupants to determine their transportation modes

D.

Provide parking for low-emitting vehicles for 5% of the building occupants

Innovation credits for exemplary performance are awarded for

A.

reaching 100% threshold

B.

demonstrating significant environmental benefits

C.

achieving the next incremental threshold

D.

demonstrating a quantitative improvement in environmental performance

The WaterSense label or local equivalent requirement in Water Efficiency Prerequisite, Indoor Water Use Reduction

ensures that eligible newly installed plumbing fixtures will

A.

be advertised as LEED compliant

B.

be both water efficient and high performing

C.

comply with mandatory federal government regulations

D.

comply with all international plumbing system requirements

The compliant value of green cleaning products and materials is calculated using what factor?

A.

Cost

B.

Weight

C.

Volume

D.

Recycled content

When tracking waste data during the performance period for Materials and Resources Credit, Solid Waste Management - Ongoing, which strategy may be used to document total and diverted waste?

A.

Measure and document waste in weight or volume

B.

Use replacement value as the metric for ongoing waste

C.

Extrapolate data from one month of the performance period

D.

Do not allow tenant waste outside the building's waste program to be included

For the Optimize Energy Performance Credit, ENERGY STAR® eligible buildings may earn

A.

1-20 points, depending on the ENERGY STAR® rating

B.

3-20 points, depending on the ENERGY STAR® rating

C.

1-20 points, depending on the degree of improvement over the national average

D.

3-20 points, depending on the degree of improvement over the national average