Weekend Sale - Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: sntaclus

How much area of wall space is needed in the telecommunications room (TR) to support a nurse call system?

A.

1.2m x 1.2 m (4 ft x 4 ft)

B.

1.2m x 2.4 m (4 ft x 8 ft)

C.

2.4 m x 2.4 m (8 ft x 8 ft)

D.

2.4 m x 3.6 m (8 ft x 12 ft)

You are designing a nurse call system for an assisted care facility. What type of nurse call system would best suit the needs for the facility?

A.

Audiovisual system

B.

Staff emergency system

C.

Tone/Visual system

D.

Bedside system

You are designing a nurse call system for a health care facility. The system will have emergency call switches. What is the first step you should take in designing the nurse call system?

A.

Properly size the supporting TR to accommodate the headend system

B.

Program the headend device for the various call switches that will be used

C.

Perform a risk assessment to determine call switch locations

D.

Perform a site survey to verify the pathways that will connect the headend device with the call switches

The ________ system is an application used for storing and viewing captured digital radiology image files.

A.

CCU

B.

ICU

C.

DICOM

D.

PACS

You are designing an interactive patient television system (IPTS) that will provide internet, nurse call and LCD television services. From the following, which medium will NOT support these services in a backbone cabling system?

A.

Balanced twisted pair

B.

Coaxial 1/2 inch hard-line cable

C.

Multimode optical fiber cable

D.

RG-11 coaxial cable

In a telecommunications room (TR), the MINIMUM bottom edge height recommendation for mounting plywood on the wall is ________ above AFF.

A.

51 mm (2 in)

B.

152 mm (6 in)

C.

200 mm (8 in)

D.

305 mm (12 in)

E.

410 mm (16 in)

In addition to voice and data services, an equipment room (ER) can be designed to include all of the following EXCEPT:

A.

CATV and CCTV facilities

B.

Life safety facilities

C.

Building electrical service monitoring and controls

D.

Audio and paging equipment

E.

General premise monitoring and security systems

You have been selected to do the telecommunications design on a new, single story building. The architect requires the size and location of the telecommunications rooms so their building design can proceed. From the items listed below (all of which are required for the design), which one is the logical starting point in order to provide the architect with a size and location for the room?

A.

Determine where the entrance facility will be

B.

Determine the number of , their locations, and telecommunications services needed

C.

Determine the power, HVAC, electrical, and security requirements for the room

D.

Determine future growth and other requirements

E.

Determine the types of equipment to be installed in the room

A building has a floor space of 16.7 m (55 ft) by 45 m (150 ft) with a common core measuring 9.17 m (30 ft) by 13.7 m (45 ft). How many individual can be provided in the usable floor space?

A.

50

B.

58

C.

69

D.

77

E.

85

A building can have multiple equipment rooms (ERs) for all of the following reasons EXCEPT:

A.

To provide redundancy

B.

For separate tenants

C.

To house different types of equipment

D.

To serve multiple Access point (APs) and/or Service provider (SPs)

E.

To accommodate office and work space