Summer Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: exc65

An architect is collaborating with a client to design a VMware Cloud Foundation (VCF) solution requiredfor a highly secure infrastructure project that must remain isolated from all other virtual infrastructures. The client has already acquired six high-density vSAN-ready nodes, and there is no budget to add additional nodes throughout the expected lifespan of this project. Assuming capacity is appropriately sized, which VCF architecture model and topology should the architect suggest?

A.

Single Instance - Multiple Availability Zone Standard architecture model

B.

Single Instance Consolidated architecture model

C.

Single Instance - Single Availability Zone Standard architecture model

D.

Multiple Instance - Single Availability Zone Standard architecture model

An architect is planning the deployment of Aria components in a VMware Cloud Foundation environment using SDDC Manager and must prepare a logical diagram with networking connections for particular Aria products. Which are two valid Application Virtual Networks for Aria Operations deployment using SDDC Manager? (Choose two.)

A.

Region-A - Overlay backed segment

B.

Region-A - VLAN backed segment

C.

X-Region - VLAN backed segment

D.

X-Region - Overlay backed segment

An architect is designing a VMware Cloud Foundation (VCF)-based Private Cloud solution. During the requirements gathering workshop with customer stakeholders, the following information was captured:

The solution must be capable of deploying 50 concurrent workloads.

The solution must ensure that once submitted, each service does not take longer than 6 hours to provision.

When creating the design documentation, which design quality should be used to classify the stated requirements?

A.

Availability

B.

Recoverability

C.

Performance

D.

Manageability

A customer has a database cluster running in a VCF cluster with the following characteristics:

40/60 Read/Write ratio.

High IOPS requirement.

No contention on an all-flash OSA vSAN cluster in a VI Workload Domain.

Which two vSAN configuration options should be configured for best performance? (Choose two.)

A.

Flash Read Cache Reservation

B.

RAID 1

C.

Deduplication and Compression disabled

D.

Deduplication and Compression enabled

E.

RAID 5

As a VMware Cloud Foundation architect, you are provided with the following requirements:

All administrative access to the cloud management components must be trusted.

All cloud management components’ communications must be encrypted.

Enhancement of lifecycle management should always be considered.

Which design decision fulfills the requirements?

A.

Integrate the SDDC Manager with a supported 3rd-party certificate authority (CA).

B.

Integrate the SDDC Manager with the vCenter Server in VMCA mode.

C.

Write a PowerCLI script to run on all virtual appliances and force a redirection on port 443.

D.

Write an Aria Orchestrator Workflow to change the ESXi hosts’ certificates in bulk.

A VMware Cloud Foundation design incorporates the following technical requirements:

All management components must have their login sessions timeout after 2 minutes of inactivity.

Communication between management components should be limited to required ports only.

Modifications required by compliancy should not impact the management components’ functionality.

What would be the recommendation from a design perspective that would aid in achieving the above requirements?

A.

Consult the vSphere Security Configuration kit

B.

Leverage the results of a vulnerability assessment and apply the recommendations

C.

Consult the Compliance Kit for VMware Cloud Foundation

D.

Apply NSX DFW (Distributed Firewall) to achieve zero-trust

Which statement defines the purpose of Technical Requirements?

A.

Technical requirements define which goals and objectives can be achieved.

B.

Technical requirements define what goals and objectives need to be achieved.

C.

Technical requirements define which audience needs to be involved.

D.

Technical requirements define how the goals and objectives can be achieved.

The following requirements were identified in an architecture workshop for a VMware Cloud Foundation (VCF) design project utilizing vSAN for its primary storage solution:

REQ001: Application must maintain a minimum of 1,000 transactions per second (TPS) during business hours excluding disaster recovery (DR) scenarios.

REQ002: Automatic DRS and HA must be utilized.

REQ003: Planned maintenance must be executed outside of business hours.

Which of the following test scenarios should be added and performed to validate these requirements?

A.

Trigger a Virtual Machine vMotion operation.

B.

Trigger a vCenter Server update.

C.

Trigger a vSAN disk group evacuation.

D.

Trigger a failure of an ESXi host.

A customer is deploying VCF at a new datacenter location. They will migrate their workloads from the existing datacenter to the new VCF platform over six months. Both datacenters will run simultaneously for six months during the migration. Which of the following should be a documented risk?

A.

Six months may not be enough time to complete the migration.

B.

There will be connectivity between the two locations.

C.

Bandwidth between the two locations is sufficient to accommodate the workload migration.

D.

Workloads will be powered off during migration.

The following requirements were identified in an architecture workshop for a virtual infrastructure design project.

REQ001: All virtual machines must meet the Recovery Time Objective (RTO) of twenty-four hours or less in a disaster recovery (DR) scenario.

Which two test cases will verify these requirements?

A.

Simulate or trigger an outage of the primary datacenter. All virtual machines must be restored within four hours or less.

B.

Simulate or trigger an outage of the primary datacenter. All virtual machines must be restored within twenty-four hours or less.

C.

Simulate or trigger an outage of the primary datacenter. All virtual machines must not lose more than twenty-four hours of data prior to the outage.

D.

Simulate or trigger an outage of the primary datacenter. All virtual machines must not lose more than four hours of data prior to the outage.