Summer Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: exc65

The Section Access security table for an app is shown. User ABC\PPP opens a Qlik Sense app with a table using the field called LEVEL on one of the table columns.

What is the result?

A.

The user gets a "Field not found" error.

B.

The table is removed from the user interface.

C.

The user gets an "incomplete visualization" error

D.

The table is displayed without the LEVEL column.

A data architect needs to load Table_A from an Excel file and sort the data by Field_2.

Which script should the data architect use?

A)

B)

C)

D)

A.

Option A

B.

Option B

C.

Option C

D.

Option D

On executing a load script of an app, the country field needsto be normalized.The developer uses a mapping table to address the issue.

What should the data architect do?

A.

Use a LEFT JOIN instead of the APPLYMAP

B.

Use LOAD DISTINCT on the mapping table

C.

Create two different mapping tables

D.

Review the values of the source mapping table

Refer to the exhibits.

While debugging an app, a developer loads data from an application layer QVD file.

In the process of separating a concatenated key into two parts, some split results are missing data

What should the data architect do?

A.

Utilize a combination of LEFT(), MID(), and RIGHT()functions to capture the key components

B.

In the SUBFIELD function, replace the ‘_’ with a ‘|’ or ‘_’ character.

While debugging an app, a developer loads data from an application layer QVD file.

In the process of separating a concatenated key into two parts, some split results are missing data

What should the data architect do?

C.

Utilize a combination of LEFT(), MID(), and RIGHTO functions to capture the key components

D.

In the SUBFIELD function, replace the '- with a ‘|’ or '-’ character

E.

Instruct the developer of the QVD file to correct the generation of the ConcatKeyAlpha field

F.

Wrap an IF() function around the SUBFIELDQ functions to check and adapt to null values character

G.

Instruct the developer of the QVD file to correct the generation of the ConcatKeyAlpha field

Refer to the exhibit.

A data architect is loading the tables and a synth key is generated.

How should the data architect resolve the synthetic key?

A.

Remove the LineNo field from Shipments and use the AutoNumber function on the

B.

Create a composite key using OrdertD and LineNo

C.

Remove the LineNo field from both tables and use the AutoNumber function on the OrderlC field

D.

Create a composite key using OrderlD and LineNo. and remove OrderlD and LineNo from Shipments