Spring Sale Special - Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: sntaclus

A customer has purchased a FlashArray//XL. What power cables are required in order to connect this array to rack PDUs?

A.

2 x C13/14

B.

4 x C13/14

C.

4 x C19/20

An Implementation Engineer runs check start validate-array-health before starting a FlashArray//X70R3 to FlashArray//X70R5 HWNDU and receives code 60 alert indicating an unhealthy NVRAM module in CH0.NVB1. What action Should the Implementation Engineer take to resolve this?

A.

Disable the unhealthy NVRAM module and proceed With HWNDU after confirming there is no degraded data.

B.

Reseat the unhealthy NVRAM module, and then verify it is in a healthy status prior to proceeding with the HWNDU.

C.

Proceed with the HWNDU, the //X70 model has a four NVRAM configuration so the array still has redundancy.

A customer has ordered several FlashArrays and wants to have ActiveCluster configured. What is the maximum quantity of arrays supported with ActiveCluster?

A.

2

B.

3

C.

4

In a situation where iSCSI cards need to be re-used during a controller upgrade, which is a valid transfer path?

A.

XR2 > XR3

B.

M > XR2/3

C.

M > XR2

What is the default FlashArray//XLR5 - FC configuration shipped for new installs?

A.

4-port 32G FC card with 32G optics installed in PCIe Slot 1; 2-Port 32G FC card with 32G optics installed in PCIe slot 3; DirectCompress Accelerator installed in PCIe slot 8

B.

4-port 32G FC card with 32G optics installed in PCIe slot 3; 2-Port 32G FC card with 32G optics installed in PCIe slot 5; DirectCompress Accelerator installed in PCIe slot 6

C.

4-Port 32G FC card with 32G optics installed in PCIe slot 4; 2-Port 32G FC card with 32G optics installed in PCIe slot 3; DirectCompress Accelerator installed in PCIe slot 5

When should a FlashArray support case be opened?

A.

Once an issue arises

B.

Once install is completed

C.

Before starting install

After running puredb run giveback --safe command once CT0 has been upgraded, how long should the Implementation Engineer wait before continuing with the controller upgrade?

A.

3 minutes

B.

5 minutes

C.

10 minutes

What is the maximum number of SAS shelves supported for FlashArray//XL?

A.

0

B.

1

C.

2

An Implementation Engineer is performing a FlashArray//X to FlashArray//XL HWNDU. After rebooting a controller, the new controller fails to reach a ready state. Which command should the Implementation Engineer run to resolve the issue?

A.

ha_sync.py --resync ipneigh

B.

hardware_check.py

C.

firewall.py --add ha rcima eth23

When installing the first DirectFlash Shelf on a FlashArray//XR2/3, what mezzanine ports are used on the controllers?

A.

ETH6 and ETH8

B.

ETH6 and ETH9

C.