An administrator receives a notification that storage in a Nutanix cluster is unavailable. The cluster consists of five nodes and is configured with a Fault-Tolerance level of 1 (FT-1).

Upon investigation, the administrator finds the following:

• All AHV hosts are powered on and the CVMs are running

• Nodes A, B, and C are connected to one top of rack switch

• Nodes D and E are connected to a second top of rack switch

• The cluster status command run on Node A shows that CVM services on nodes D and E are down

Which issue is causing the storage outage?

A.

The default gateway for the CVMs and AHV hosts is down.

B.

The switch connecting Nodes D and E is down.

C.

The genesis process is down on both Nodes D and E.

D.

Nodes D and E are in maintenance mode.

An administrator has Created a new VM, but When accessing the console to monitor the guest install, the administrator sees the effect shown in the exhibit.

What is the likely cause of this issue?

A.

The Wrong type of disk was specified

B.

the installation media was not mounted

C.

the nutanix virtIO driver was not mounted

D.

The boot order is incorrectly configured

An administrator recently added in 3 nodes to an existing 5 node cluster. While 1 node came with its own block, the other 2 nodes where added to an existing share. After adding the nodes, the administrator sees that the hardware tab displays the correct number of nodes, but incorrect position in the diagram tab.

What should the administrator do to resolve the issue?

A.

Check the factory_config.json for all 3 nodes

B.

SSH into CVM and perform genesis restart on each CVM

C.

SSH into the CVMs and run genesis acropolis stop; cluster start

D.

Check the factory_config. json for the two single nodes.

A customer has Metro Availability configured in Automatic Resume Mode between Site A and Site B What happens to VMs if Primary Site A has full network failure?

A.

Automatic protection domain promotion in Site B. VMs automatically restart in Site B

B.

VMs continue to run on Site A following an automatic disable of protection domains.

C.

An administrator must unwitness in Site B and promote protection domains in Site B for VMs to restart

D.

An administrator must promote protection domains in Site B for VMs to restart.

An administrator needs to provide data integrity at the application level for a VM that is replicated to a secondary site.

Which requirement will satisfy this task?

A.

1 VM per Availability Zone

B.

1 VM per Consistency Group

C.

1 VM per schedule

D.

1 VM per Protection Domain

An administrator is managing two AHV and vSphere-Based Clusters. The administrator is able to install a Windows Guest OS from an ISO Image to VMWare VMs , but is unable to do the same activity with AHV VMs.

What should the administrator do to successfully perform this action with AHV VMs?

A.

Change VM Setting From BIOS to UEFI

B.

Provide virtIO Drivers

C.

Verify cluster iSCSI data Services IP

D.

Manag Nutanix Guest tools

A customer has NearSync configured. When the administrator tries to restore a snapshot from 3 minutes ago, it is not available. The snapshots are happening at 15-minute intervals instead of at the 5-minute configured interval. When the protection domain was initially set up, the snapshots were happening at the expected 5-minute interval.

What should the customer do to enable the snapshots to happen at the expected interval?

A.

Utilize Metro Availability to meet this requirement

B.

Change the protection domain to use Async DR

C.

Fix a connectivity issue because the protection domain reverted to Async

D.

Configure the protection domain to take snapshots on 15-minute intervals

Refer to the exhibit.

An administrator receive the warning massages shown in the exhibit while validating cluster conversion from EXSi to AHV.

What should the administrator do to address this warning in v Center Server?

A.

Keep active adapters od different speeds as active standby

B.

Remove adapters that are active but not homogeneous.

C.

Keep homogeneous adapter as active and standby

D.

Remove the standby adapters under Teaming and Failover.

How should an administrator view the storage consumed by the recycle bin?

A.

On the storage Overview dashboard

B.

In the Cluster Details Page of the cluster setting

C.

On the storage Summary Widget on the Prism Dashboard

D.

In the Diagram or Table view on the Storage dashboard

A customer recently set up Async Replication between Site A and Site B. The customer wants to conduct a planned failover and clicks Activate on Site B.

The customer then runs the following command on Site A:

ncli pd deactivate_and__destroy_vms name=

What does this do to the customer environment?

A.

VMs get deleted from Site B. and the protection domain is now Active.

B.

VMs are powered off on Site A and must be manually powered on at Site B.

C.

VMs get deleted from Site A and the protection domain is no longer active.

D.

Customer must then manually power off VMs at Site A and power them on at Site B.