Your customer requires a way to monitor a high-level and holistic view of the workload of their servers. A database server was identified as providing lower than expected performance after migrating to a PowerEdge R760 server. Which option can be selected in iDRAC to monitor this level of information?

A.

CPU Utilization

B.

I/O Utilization

C.

Memory Utilization

D.

System Level CUPS Index

A company operates a Dell PowerEdge server configured with a RAID 10 virtual disk that hosts critical databases services. Monitoring tools indicate that the virtual disk usage has reached 95% of total capacity. The server provides 24/7 mission-critical services, so downtime must be minimized or completely avoided. Currently, the server has only one empty drive bay remaining. What should the operations team consider first to safely plan the expansion of the RAID 10 virtual disk?

A.

Check the RAID controller's capabilities, available drive bays, and whether expansion is supported.

B.

Replace the RAID controller with the latest model to guarantee maximum performance, then add the new disk.

C.

Add the new disk, trigger a rebuild of the RAID, and wait until the rebuild is complete before using the expanded capacity.

D.

Add the new disk and immediately perform Online Capacity Expansion through iDRAC.

You have replaced a failed drive in slot three for the second time but it's not detected by the PERC. A diagnostic test using the PERCCLI utility indicates that other drives are working properly. What is a possible issue?

A.

iDRAC licensing

B.

PERC controller is faulty

C.

PERC firmware level

D.

Backplane or slot connection fault

You are in a dark site with a PowerEdge server that shows an amber light. iDRAC Is not configured for network access but the OS is installed and has RACADM for access to the iDRAC card. What RACADM command can be used to help identify the cause of the amber light?

A.

getsel

B.

getssninfo

C.

getsysinfo

D.

get led

You are managing a PowerEdge R570 and iDRAC is not reachable on the Network. You need to collect iDRAC details on the server. Which two tools will allow you to get the iDRAC details?

A.

Use RACADM to capture inventory and log

B.

Use iSM to capture inventory and log

C.

Use Lifecycle Controller to capture inventory and log

D.

Use OME to capture inventory and log

A system administrator must update the virtual console security settings on their PowerEdge server to comply with company standards. The company requires strong encryption and secure access policies. Which setting meets these requirements?

A.

Use a strong password

B.

Disable SSL encryption for faster performance

C.

Configure an acceptable timeout value

D.

Set SSL encryption to 256-bit or higher

In order to Improve efficiency of the Data Center, the IT department has been tasked with auditing the health and performance, including any sensor alerts, for all Dell servers from the past quarter. Which two basic actions must be taken on the servers in order to obtain the requested information?

A.

Apply iDRAC Enterprise License

B.

Acquire appropriate Login privilege

C.

Set iDRAC networking to use DHCP

D.

Enable RACADM

On a Dell PowerEdge 16G server, iDRAC is configured to use a shared LOM port. What happens if the Auto-Dedicated NIC option is enabled and a dedicated NIC becomes available?

A.

iDRAC uses both the shared LOM and dedicated NIC simultaneously for redundancy

B.

iDRAC automatically switches to the dedicated NIC without requiring a reboot

C.

iDRAC disables network connectivity until manually reconfigured

D.

iDRAC continues using the shared LOM port until the next reboot

After updating BIOS and NIC firmware using Lifecycle Controller, a PowerEdge server boots into Lifecycle Controller instead of the OS, although the OS disks are intact. What is the most likely root cause?

A.

Boot mode was changed

B.

RAID metadata corruption

C.

Secure Boot certificates expired

D.

iDRAC lost network connectivity

A Dell PowerEdge R750 shows a sudden reduction in usable capacity on a RAID 6 virtual disk after replacing a failed drive with a larger one. The OS and iDRAC both report the VD as “Ready’" and “Optimal" but usable capacity remains unchanged. What is the cause of this behavior?

A.

The drive was added as a dedicated hot spare instead of a member disk

B.

The virtual disk remains limited by the smallest disk

C.

The rebuild failed and the virtual disk is using reduced capacity mode

D.

The virtual disk automatically expanded but the OS has not refreshed