A design for a WELL building has an entryway system composed of grilles that measure the width of the entrance and 10 ft. (3 m) long in the primary direction of travel. This design can meet healthy entryways by

A.

including healthy signage at the entrance

B.

incorporating revolving doors at the entrance

C.

including effective mechanical ventilation at the entrance

D.

separating common outdoor areas from building entrances

A permanently installed an conditioner was used during construction What should be done to this equipment prior to occupancy?

A.

Tighten the fan bolt

B.

Replace me air finer

C.

Clean the condenser coil

D.

Recharge the refrigerant circuit

A project team wants to provide compliant cycling infrastructure for its occupants to fulfill a WELL feature. Which of the following should the team implement?

A.

The project is located near a bike network that connects riders to five use types

B.

Long-term bike parking (e.g., bike room) can accommodate at least 2.5% peak visitors

C.

The project is located in an area (zip or postal code) with a minimum Bike Score® of 40

D.

Short-term bike parking (e.g., outdoor bike racks) is available for at least 2.5% of peak visitors

A project satisfies requirements lot Feature V10: Self-Monitoring Part 1 if it provides eligible employees with self-monitoring tools mat are subsidized by at least

A.

10%

B.

29%

C.

33%

D.

50%

In Feature S01: Sound Mapping, Part 1: Label Acoustic Zones, which of the following zones needs to be labelled in the annotated document submission?

A.

Entry zone

B.

Mixed zone

C.

Exterior zone

D.

Amenity zone

A project registered under WELL Core Certification has a total area of 100.000 ft3 (9 290 m2). What is the minimum of the total building floor area that should be available tor performance testing?

A)

B)

C)

D)

A.

Option A

B.

Option B

C.

Option C

D.

Option D

An office building is at the design stage. The client has the goal of achieving acceptable thermal environment for building occupants. Which of the following strategies should the WELL AP suggest to address this goal and meet the requirements of a WELL feature?

A.

Utilize natural conditioning when the prevailing mean outdoor temperature is 48°F (9C)

B.

Design a radiant ceiling, wall or floor heating/cooling system for at least 45% of the regularly occupied project area

C.

Include real-time displays of dry-bulb temperature and relative humidity for 50% of regularly occupied spaces and make available to occupants through display screens

D.

Design mechanically conditioned regularly occupied spaces to meet predicted mean value range of +/- 0.5 for at least 90% of occupied hours and regularly occupled spaces

Based on the WELL Building Standard™, what is a possible contributing factor to Type 2 diabetes?

A.

High consumption of seafood

B.

Low fruit and vegetable intake

C.

High consumption of caffeinated beverages

D.

Low consumption of sugar sweetened beverages

A project administrator is preparing documentation for a project's submittal. In addition to the Letters of Assurance, what other documents must the project administrator submit to support the features being pursued?

A.

Survey data

B.

Annotated documents

C.

Certificate of occupancy

D.

Air and water testing results

A project successfully received both LEED® and BREEAM® certification. The project's WELL Certification is managed by two WELL APs. How many additional points would the project need to achieve the full score under Innovation?

A.

Two points

B.

Three points

C.

Four points

D.

Five points