Fusionllodule2000 UPS is listed, configuration (

A.

Integrated UPS cabinet

B.

Integrated power distribution cabinet

C.

Precision power distribution cabinet

In which of the following areas does the AHU scheme have the worst application effect (

A.

Xinjiang

B.

Beijing

C.

Harbin

D.

Hainan

The capacity management module of the NetEco management system can connect with third-party () systems, accept equipment change information, automatically generate a change application form and track the processing process?

A.

NMS

B.

ITSM

C.

CRM

D.

EMS

The UPS5000E-300K (50kVA power module) mainframe occupies a small area, saving space in the computer room, and the area is only ? ( )

A.

1 square meter

B.

1.5 square meters

C.

0.8 square meters

D.

0.5 square meters

What kind of circuit breaker is used in the main circuit of the PDU8000 precision power distribution cabinet:

A.

Molded case circuit breaker

B.

Miniature circuit breakers

C.

Frame circuit breaker

D.

isolating switch

The NetEco6000 management system can provide the temperature cloud map function to realize the identification of cold and hot spots in the computer room. How many layers does the temperature cloud map support?

A.

Single layer

B.

Double layer

C.

Three floors

D.

Fourth floor

The "one-click fault collection" function of Huawei's precision air conditioner touch screen, the following description is wrong:

A.

Can export EXCEL format file

B.

The function is only available for row-level air conditioners

C.

The fault record data can be exported through U disk

What are the incoming line methods supported by UPS5000-A-400/500K? ( )

A.

Downstream

B.

Top entry line

C.

Compatible with upper and lower incoming lines

The access door types of Huawei Fusionmodule2000 V3.0 version are ( )

A.

Sliding door

B.

revolving door

C.

Electric door

D.

have both.

When the Netfco management system adopts the single 6RH1585 server, it can support the maximum access (10,000 test points, so as to realize the centralized management of multiple data centers?

A.

20

B.

40

C.

50

D.

100

The UPS5000-E has the function of adjusting the number of battery cells, which avoids the failure of a single battery to cause the replacement of the entire group, and solves the problem of difficult maintenance of

traditional UPS batteries. May I ask how many cells can be adjusted in the UPS5000-E (50kVA module)? ()

A.

30-40

B.

32-40

C.

32-42

D.

30-44

UPS000-A/E 400KVA and above models are divided into standard version and enhanced version, of which the standard version comes standard with ( ) isolating switch

A.

Main input

B.

Bypass Input

C.

Maintenance

D.

output

UPS5000-E (50kVA module) series UPS does not derate backup power, the number of 12V batteries in the following configuration, ( ) is unreasonable. /

A.

Section 34

B.

Section 38

C.

Section 40

D.

Section 36

What is the channel width of Huawei Fusionmodule2000 ( )

A.

1000mm

B.

1100mm

C.

1200mm

D.

1300mm

UPS5000-E can easily realize N+X power supply system by only selecting ( ) , and the operation is simple and convenient. .

A.

BSC cable

B.

Parallel cable

C.

BSC Control Board

D.

Parallel card