Regarding the characteristics of the FusionModule2000 row-level air conditioner, which of the following descriptions is wrong? ( )

A.

Only 42KW supports wet film humidification function

B.

Both 25KW and 42KW support wet film humidification function

C.

Both 25KW and 42KW support light-load dehumidification

function

Which of the following statements are true about the iBattery battery management system? ()

A.

iBattery can manage battery

B.

iBattery can be connected to UPS

C.

iBOX can be powered by DC 48V or POE

D.

The iBat signal is wirelessly connected to the iBOX

UPS5000-A-500K Regarding efficiency, which of the following options is correct?

A.

Efficiency 96%

B.

Efficiency 94%

C.

ECO mode 99%

D.

ECO mode 98%

A project requires the management system to access a third-party generator set, two smart meters 1 (same model), and two precision air conditioners (same model), then the management

system needs to report () a third-party equipment access fee ? (

A.

1

B.

3

C.

5

D.

None of the above is true

UPS5000-E can maintain high efficiency in a wide load range and effectively reduce losses. Among them, the efficiency can reach 96% at 40% load, and the efficiency can

reach 95% at 20% load. What is the efficiency in ECO mode? ( )

A.

97%

B.

99%

C.

96%

D.

98%

Which of the following communication functions does the UPS5000-E include? () (multiple choice)

A.

Dry contact card

B.

RS485

C.

SNMP

D.

RS232

Which of the following voltage systems does the UPS5000-E support?

A.

380V

B.

480V

C.

415V

D.

400v

Which of the following alarm functions does the main circuit of the PDU800 power distribution cabinet have? ()

A.

Current high reading value out-of-limit alarm

B.

Overvoltage alarm

C.

The main circuit is powered off

D.

Abnormal frequency

E.

Undervoltage alarm

What is the function of the multi-function sensor? ( )/

A.

smoke

B.

Temperature and humidity detection

C.

Infrared light detection

The number of group controllers for Huawei NetCol series smart cooling products is ()

A.

24

B.

12

C.

16

D.

32

FusionModule2000 product configuration framework, including which of the following (

A.

Cabinet System

B.

Power supply and distribution system

C.

Monitoring System

D.

Refrigeration system

When multiple FusionModule products are used in the same project, when configuring NetEco, the associated application scenario should be selected ()

A.

Customize

B.

FusionModule2000

C.

Associate the FusionMoudle family

D.

FusionMoudle5000

UPS2000-G-(6K-20K) Regarding the optional output isolation transformer, the following statements are correct () (multiple choice)

A.

Can be connected to output isolation transformer

B.

Can be used as input isolation transformer

C.

It can convert one channel of 220V into two channels of 110V

D.

Can convert 50Hz to 60Hz Output

The NeEco6000 management system can provide monitoring of the cooling power system. Which of the following functions can it provide? (Multiple choices)

A.

The power distribution system topology diagram can be provided, and the power distribution system diagram of the entire computer room can be displayed

B.

Support the display of key equipment indicators on the power distribution topology diagram, which is convenient for users to understand the operation status of the system and important nodes

C.

It can provide the topological diagram of the chilled water system, showing the operation status of the whole system

D.

None of the above is supported

Regarding the monitoring software NetEco1000U, the following statements are correct ()

A.

Monitor the working status of the UPS in real time and operate the UPS

B.

Support USB, SNMP, MODUBUS network communication

C.

Email alarm, SMS alarm and other alarm reporting functions

D.

SMS alarm needs to be equipped with SMS cat

E.

Provided for free, download and use the answer from the Huawei Support website

as needed