Summer Sale Special - Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: sntaclus

Which statement about the HPE D3940 storage module is true?

A.

Only one type of drives (SATA, SAS, SSD) can be installed in each module.

B.

It is configured through CLI available from HPE Synergy console.

C.

SATA drives require redundant IO adapters to be installed in this module.

D.

Up to five modules can be installed in a single frame with Gen10 servers.

A junior architect designed a solution based on HPE Synergy that must meet the following requirements:

    Support at least 30 HPE Synergy 480 Gen10 Plus compute modules

    Interconnect modules must provide MAC and WWN virtualization

    All HPE Synergy frames must formulate a single management entity

    The management appliance should not be a single point of failure

    Connectivity to FC array should be available to all compute nodes

The proposal consists of:

    3 HPE Synergy 12000 frames

    6 HPE Composer 2 modules

    2 HPE Virtual Connect SE 100Gb F32 Module

    4 HPE Synergy 50Gb Interconnect Link Module

Which statements about this proposed design are true? (Select two)

A.

FC upgrade licenses for HPE Virtual Connect SE 100Gb F32 Module must be added.

B.

HPE Synergy 50Gb ILMs must be replaced with HPE Virtual Connect SE 100Gb F32 modules.

C.

Remove 4 HPE Composer 2 modules from the design, as they are not required.

D.

The selected interconnect modules do not provide the requested WWN virtualization.

E.

The current setup can support up to 18 HPE Synergy 480 Gen10 Plus compute modules.

Your customer has an HPE Synergy frame equipped with a D3940 Storage Module. Each of the compute nodes has an appropriate storage controller Installed and two 12Gb SAS switches installed in the first fabric.

The customer reports that compute nodes cannot access the storage module. What should you verify first when troubleshooting this problem?

A.

If the D3940 module is imported in managed state that allows volume provisioning.

B.

If there Is a logical interconnect created based on the 12Gb SAS switches.

C.

If the D3940 storage module is property licensed through HPE OneView interface.

D.

If there is at least one ISCSI network configured that will provide access to the module.

An organization wants to deploy a computer vision model to analyze security video.

Which NVIDIA GPU is well suited to this use case, providing the necessary performance in a cost effective manner?

A.

NVIDIA H100

B.

NVIDIA GH200

C.

NVIDIA L4

D.

NVIDIA P100

An HPE Synergy customer needs to prevent a timeout and loss of communication during an external switch firmware upgrade.

Click the parameter that the customer should configure within an uplink set to meet this requirement

Your customer has an HPE Synergy frame equipped with a D3940 Storage Module. Each of the compute nodes has the appropriate storage controller installed and two 12Gb SAS switches installed in the first fabric.

The customer reports that the compute nodes cannot access the storage module.

What will you verify first when troubleshooting this problem?

A.

If the SAS logical interconnect is a part of the logical enclosure and has a healthy state.

B.

If the D3940 module is imported in a managed state that allows volume provisioning.

C.

If there is at least one iSCSI network configured that will provide access to the module.

D.

If the D3940 storage module is properly licensed through the HPE OneView interface.

Your customer is trying to grow a VMware duster using HPE OneView for VMware vCenter Server. They get an error and cannot proceed

Which tool should you use to troubleshoot the problem?

A.

HPE One View for VMware vCenter Server to verify if server profile template s property imported and registered

B.

vCenter Server to verify if an OS Bund Plans property defined and has ESXi image uploaded

C.

HPE OneView interface to import an existing cluster using the hypervisor cluster profile functionality.

D.

ILO interlace of a given HPE Synergy compute node to verify whether this node is registered within HPE Oneview.

You configured a virtual machine cluster using the HPE Storage Integration Pack for VMware vCenter.

Click the option in the SSMC main menu that you can use to verify whether a virtual storage operation is properly created on HPE Primera or 3PAR.

A company has an HPE Synergy enclosure with several Genu compute modules and D3940 storage modules installed in it. What is one requirement for the compute modules to use drives on the storage modules?

A.

An HPE Virtual Connect FC module is installed in interconnect bay 2.

B.

A SAS Connection Module is installed in interconnect bay 2.

C.

The compute modules have the correct model of storage controller installed In mezzanine 1.

D.

The compute modules have FC-capable HBAs installed in mezzanine 1.

Match HPE SimpliVity team with the definition.