An administrator is investigating a physical server mat will not Boot into the OS. The server has three hard drives configured in a RAID 5 array. The server passes POST, out the OS does not load. The administrator verities the CPU and RAM are Doth seated correctly and checks the dual power supplies. The administrator then verifies all the BIOS settings are correct and connects a bootable USB drive in the server, and the OS loads correctly. Which of the following is causing the issue?
A server administrator has been creating new VMs one by one. The administrator notices the system requirements are very similar, even with different applications. Which of the following would help the administrator accomplish this task in the SHORTEST amount of time and meet the system requirements?
A server administrator is completing an OS installation for a new server. The administrator patches the server with the latest vendor-suggested software, configures DHCP, and verifies all network cables are properly connected in the IDF, but there is no network connectivity. Which of the following is the MOST likely reason for the lack of connectivity?
A remote physical server is unable to communicate to the network through the available NICs, which were misconfigured. However, the server administrator is still able to configure theserver remotely. Which of the following connection types is the server administrator using to access the server?
A server technician has received reports of database update errors. The technician checks the server logs and determines the database is experiencing synchronization errors. To attempt to correct the errors, the technician should FIRST ensure:
Which of the following policies would be BEST to deter a brute-force login attack?
A recent power Outage caused email services to go down. A sever administrator also received alerts from the datacenter’s UPS.
After some investigation, the server administrator learned that each POU was rated at a maximum Of 12A.
INSTRUCTIONS
Ensure power redundancy is implemented throughout each rack and UPS alarms are resolved. Ensure the maximum potential PDU consumption does not exceed 80% or 9.6A).
a. PDU selections must be changed using the pencil icon.
b. VM Hosts 1 and 2 and Mail Relay can be moved between racks.
c. Certain devices contain additional details
A technician is trying to determine the reason why a Linux server is not communicating on a network. The returned network configuration is as follows:
eth0: flags=4163<UP, BROADCAST,RUNNING,MULTICAST> mtu 1500
inet 127.0.0.1 network 255.255.0.0 broadcast 127.0.0.1
Which of the following BEST describes what is happening?
A technician runs top on a dual-core server and notes the following conditions:
top –- 14:32:27, 364 days, 14 usersload average 60.5 12.4 13.6
Which of the following actions should the administrator take?
A technician is attempting to reboot a remote physical Linux server. However, attempts to command a shutdown -----now result in the loss of the SSH connection. The server still responds to pings. Which of the following should the technician use to command a remote shutdown?