What is the insertion loss guideline for a multimode mechanical splice?

A.

0.05 dB

B.

0.1 dB

C.

0.3 dB

D.

0.5 dB

E.

1.0 dB

What is the connector of choice for Series 59, Series 6, and Series 11 applications?

A.

F-Style

B.

Bayonet Neill-Conncelman (BNC-Style)

C.

N-Style

D.

SMA

E.

Ultra high frequency (UHF)

Which of the following is true about screened twisted pair cable assemblies?

A.

The drain wire and screen foil must be bonded at one end only.

B.

The drain wire and screen foil must be bonded at every connection.

C.

There is no need to bond the screen foil or drain because it is not important.

D.

The drain wire and screen foil must be separately bonded at opposite ends.

Which of the following is NOT a design consideration for broadband video distribution?

A.

Amplifier link budgets

B.

Adhering to the 90 meter (295 feet) rule for horizontal distribution

C.

Amplifier cascade limitations

D.

Environmental factors

E.

Drop length

You are extending 1000 MHz video service from your existing headend to a new equipment room (ER). Your existing incoming video signal is plus (+) 15 dBmV. You have three two-way splitters with a total of minus (-) 15 dB. You are adding 122 m (400 ft) of series 11 (RG 11) cable with a minus (-) 18 dB with eight single end F-connectors with a total of minus (-) 1.2 dB. From the selections below, what is the MINIMUM gain amplifier required in the headend room?

A.

Plus (+) 15 dB

B.

Plus (+) 20 dB

C.

Plus (+) 25 dB

D.

Plus (+) 30 dB

E.

Plus (+) 35 dB

The information technology system (ITS) designer should design conduits entering a building from below grade point to extend ________ above finished floor (AFF).

A.

51 mm (2 in)

B.

100 mm (4 in)

C.

152 mm (6 in)

D.

203 mm (8 in)

E.

254 mm (10 in)

An outside plant (OSP) cable must be placed under a pipeline with two side by side pipe runs. The distance between the outside pipes is 6 m (20 ft). What is the length of the conduit required to facilitate the pipeline crossing?

A.

6 m (20 ft)

B.

7.6 m (25 ft)

C.

9 m (30 ft)

D.

10.7 m (35 ft)

E.

12 m (40 ft)

To reduce the chance of an accidental dig-up, plastic warning tape should be placed a MINIMUM of _________ below grade, but high enough above cables to allow detection before cables are damaged.

A.

101 mm (4 in)

B.

203 mm (8 in)

C.

300 mm (12 in)

D.

381 mm (15 in)

E.

457 mm (18 in)

The MOST common medium used to provide service to the access point (AP) is ________ cable.

A.

Singlemode optical fiber

B.

Multimode optical fiber

C.

Unbalanced twisted pair

D.

Balanced twisted pair

Vertical conduit masts (with approved service heads) are limited to drop-wire attachments of up to ________ lines.

A.

4

B.

6

C.

12

D.

25